NH Research 9300 High-Voltage Battery
$3,000.00
- Operating States: Charge (Source), Discharge (Load), Standby, Battery, Emulation
- Charge/Discharge Modes: Constant-Voltage (CV), Current (CC), Power (CP), Series Resistance (CR)
- Charging Envelope: 0 - 600V/±333A, 0 - 1200V/±167A
- Voltage Accuracy: 0.025% Set + 0.025% Range
- Current Accuracy: 0.1% Set + 0.1% Range
- Slew Rate: Same polarity 10 - 90% < 2mS Low Range, < 3mS High Range
- Current Change Time: < 5mS
- Current Reverse Time: < 10 mS
- Parallelability: Synchronous control for up to 12 channels (1.2MW)
- Development Source: Touch-Panel, Import from Excel or User's System Controller
- Max. Steps: 1000
- Min. Time Delay: 50μS
- Max. Step Delay: 1mS - 7 days
- Local User Interface: Touch-Panel with graphic meters & controls plus Macro screens
- Ext. Sys. Communication: LAN (Ethernet)
- Drivers (Win XP, Win 7): LabVIEW, IVI-COM, IVI-C
- Analog Current Monitor: 0 to +10V charge/0 to -10V discharge
- Analog Voltage Monitor: 0 to +10 full scale voltage
- Connectors: Main power through buss bars
- Dimensions: 78 x 28 x 39" / 1981 x 711 x 991 mm
- Weight: 1200 lbs / 544 kg
- Operating Temperature: 0 - 35°C full power
- Input Power: 3 Ø, 50 - 60 Hz, 380VAC/200A or 480VAC/160A. Output Power reduced to 90kW below 360VAC input
A programmable DC power supply designed to operate as a regenerative DC load in battery pack testing with a power range of 100kW – 2.4MW. NHR 9300 high-voltage batter testers are quick, efficent, fully programmable and bi-directional DC power sources. A modular series, NH Research 9300 power supplies can be chained together in groups of up to 24 100kW units for a total of 2.4MW.







Reviews